Hotline:021-60839008

Magnetic holding relay module

Location Position:Home > Products & Applications

4-circuit 16A magnetic hold lighting switch module DK2000-CSN0416M

  


2-1  Product overview

DK2000-CS****M is a product with LCD Chinese display interface, programming free, menu setting, and independent use of intelligent lighting control module, its 50A magnetic holding relay, itself low power consumption, small heat, but also can maintain the original output state after power off. Each relay comes with a mechanical handle. Even if the module fails unexpectedly, it can also realize the manual forced switch of the lighting circuit through the mechanical handle. It is a switching control module designed specifically for the currently widely used LED lights, outdoor high-power lamps and motor loads, which can resist instantaneous surge current up to 500A. It effectively solves the problem that the lamp can not be turned off due to the stickiness of relay contacts which is common in the market. It can provide safe and reliable intelligent control for the lighting system of national substation, hospital, subway, high-speed railway station, airport, sports stadium, hotel, large shopping mall and other important public places.
Through RS485 MODBUS RTU, TCP/IP and other national standards open communication protocol networking, to achieve the remote centralized management of computer, mobile APP.
It can also combine with Shanghai DI Control cloud platform, and realize wireless communication management of each intelligent lighting control module through 4G signal transceiver module (DTU), which is very suitable for outdoor lighting system, old building lighting system transformation, home intelligent control and so on.



2-2  Product features are as follows:

1.Use aluminum alloy shell. To improve heat dissipation and protection performance

2.The controller has independent timing.Astronomical clock.Fire protection linkage is strong.Scene editing.Manual operation and other functions

3.The controller comes with LCD screen, Chinese menu operation interface, so that users can achieve local operation management in special or emergency situations

4.Come with the controller2The channel digit input port is2DIand2Channel analog signal input port is2AI. Can be connected with fire signals, human body induction signals, illuminance, etc., to achieve automatic control

5.The relay adopts the resistance type load breaking ability in50AAnd above high power magnetic holding relay, resistance to instant surge current500AAnd above

6.The relay has a mechanical toggle switch, even if the controller fails to use, and in the case of power failure can be opened or closed by mechanical handle lighting circuit

7.The circuit current detection function: when the actual current value of a circuit is lower than the normal current value.It indicates that there is a lamp failure in the circuit, and the alarm window is opened to remind personnel to overhaul(Current detection module only)

8.All have zero disconnect function: to ensure that the loop with load work disconnected, are close to the current value 0A When the load is disconnected, the relay contact plays a good protective role

9.Circuit current limiting function: when the actual current of a circuit exceeds the set value, the relay will automatically cut off to protect the safety of the line (current detection module only).

10.The cumulative number of relay action function: refer to the number of relay action, combined with the background software, can know the use time of the lamp, can be reasonably exchanged, prolong the service life of the lamp; In addition, energy consumption can be calculated according to the lamp power.


2-3  Architecture Diagram of intelligent Lighting System:




2-4  Product specifications and technical parameters


Power consumption:                                     DC 24V / 6VA

Environment/Use:                                        -25 to 60°C; 10 to 85% RH

Storage environment:                                   -25 to 80 °C; Less than 90% RH

Man-machine interface:                               12864LCD screen "menu/confirm", "up", "down", "left" and "right" buttons

Microprocessor:                                           ARM series single chip microcomputer watchdog device automatic return.

Relay output:                                               50A high power magnetic holding relay.

Communication mode:                                1xRS-485 1/2 duplex/Modbus RTU Protocol

Communication rate:                                   9600~76.8k bps (factory/recommended 9600 bps)

Maximum communication distance:           4000 ft (1.2 km).

Communication signal input:                      RS485 Modbus RTU

Communication address setting range:       Up to 16, that is, a panel can be connected to a maximum of 16 controllers (32 can be customized)

Output specifications:                                 Each loop can output A maximum of 16A/20A/25A three specifications

Communication signal connection head:   5PIN terminal

Installation:                                                 Standard DIN35mm electric track

Product size:                                               162(W)*90(H)*63(D)mm


The four 16A/20A/25A magnetic holding switch modules have the same dimensions, as shown in the figure below:





2-5  Controller Hardware Description (Using 8-channel magnetic hold switch module as an example)

DK2000-CSN0816M Controller Hardware Description (Using the 8-channel magnetic hold switch module as an example)

project

name function remarks

1

LCD screen

Man-machine interface, display and set related functions

2

Press Up

Adjust the value/status of a set parameter

3

Press Down

4

Key Left

Move the menu and select the desired menu item

5

Key Right

6

Press Enter

The 'Confirm' button, when a menu or option is selected, will be backfired.

7

The manual forced circuit back fails On-loop forced closure; OFF- The loop is forcibly disconnected To ensure safe operation, use a tool such as a driver

8

Wiring terminal 24+, 24- Power DC24V input Power Power indicator. The indicator is on during normal operation

9

Two groups of wiring terminals communicate D+,D-, and GND


RS485 communication cable. D+ is connected to the communication line; D- Connect the communication line negative. One group in, one group out. Tx and Rx indicators. When the communication is normal, the two indicators blink

10

Wiring terminals DI1, DI2, COM Passive switch input DI1,DI2, COM is the common terminal. Can access human body induction, fire alarm and other dry contact signals to achieve automatic control

11

Terminal AI1,AI2,AIG Analog signal input AI1,AI2, AIG is the common end. Input sources can be 0-10v,4-20mA, or NTC sources. Can access illuminance, temperature and other analog signals to achieve automatic control

12

Terminal DO1-DO8

8 circuit switching output (same for 4,6,12 models)


2-6  Photos of the distribution box (The following is the layout of the 12-way magnetic holding switch module for reference only)