Dimming control module

Location Position:Home > Products & Applications

6-circuit 10A high-power front dimmer box

  

2 -Product introduction

Frontier power dimmer through input 0/1-10V signal, can be incandescent lamp, 220V halogen lamp, and equipped with adjustable optoelectronic transformer low-voltage halogen lamp dimming, power dimmer single loop output power can reach 2KW.

Model: DK2000-CDV0610L

Power supply: AC 380V

Control signal input: 0/1-10V

Output: 220V 50HZ

Output power: 2KW * 6 channels


2 -2 Product characteristics

  • 0/1-10V low voltage control, safer

  • Multiple temperature protection, safe and reliable

  • Dimming output is stable, rise time ≥200us

  • When the temperature reaches 75±5°C, the output brightness is reduced by half

  • Hanging type installation, convenient construction

  • When the temperature reaches 85±5°C, turn off the output of the dimmer

  • There are feeding holes on the upper, lower and back to adapt to various feeding methods

  • Three-phase or single power supply can be used

  • Equipped with manual automatic switch, manual switch and dimming

     

2 -3 Technical parameter

Model DK2000-CDV0610L Dimming rise time 220us in 220V

Power supply voltage 380V, 50HZ external size 340*280* 130mm

Signal input 0/1-10V Weight 8.6KG

The minimum load is 60W

Output load 0-220V shell material, color iron, black

Power output 2KW*6 Protection IP 20, EN 60 529

Output current 10A*6 Standard CE

Terminal wire diameter: 2.5-4.0 mm2 Operating temperature range 0 -- +45°C

Type of load                     




 

2 -4 Mounting size (mm)


 

2-5 Wiring terminals

DK2000-CDV0610L Controller hardware description

project

name

function

remarks

1

L1

AC380V Firewire input

2

L2

AC380V Firewire input

3

L3

AC380V Firewire input

4

N

Zero line input

 

5

1-6 group dimming output

Six 220V dimming output circuits

 

6

Signal input 0/1-10V

Input 0/1-10V signal

 

7

Ground wire

ground

8

Manual dimming

Manually start loop output and close

 

9

Indicator light

The indicator lights up during normal operation



2 -6 Wiring diagram

 

2 -7 Installation and debugging

 

  • Wiring specification

  • Power phase cable: red 2.5-6mm2 copper conductor

    Neutral wire: light blue 2.5-6mm2 copper conductor

    Ground cable: yellow and green 2.5mm2 copper conductor

  • Load cable: Copper conductor with more than 4mm2

  • 0/1-10V: 1.0 to 1.5mm2 shielded twisted pair cable

  • Open the product package, take out the paper pattern in the package, drill holes in the bearing wall, install expansion screws, and then fix the power dimmer on the wall

  • Connect each input terminal, output terminal, 0/1-10V terminal according to the wiring diagram

  • When three-phase power balance is satisfied, single-phase power supply can also be used for input power supply, and the input line of a single power supply is connected to three input terminals at the same time (input terminals in parallel).

  • Turn the lights on and off or dimmer by pressing six buttons on the panel. When 0/1-10V sends the corresponding signal, the corresponding (5) will output a corresponding voltage

Please consult our relevant technical staff for details!